- Technical Parameters
| Item No. | Parameter Name | Technical parameters |
| 1.1 | Equipment Name | Touch screen-Type Salt Spray chamber |
| 1.2 | Equipment Introduction | The touchscreen salt spray test chamber features a high level of automation and high-precision test methods. Compared with ordinary key-type salt spray chambers, it not only saves operators a great deal of management time but also minimizes test errors caused by human factors. It is equipped with an innovative human-machine interaction management mode, precise test temperature zone setting, and intelligent automatic water replenishment function.
Meanwhile, strict quality control is implemented throughout the production process. In view of the special corrosive environment the salt spray chamber operates in, all electronic components are sourced from well-known domestic or international brands. The assembly adopts a fully enclosed design, and every detail is meticulously crafted based on extensive production experience. |
| 1.3 | Equipment Model | BS-90C |
| 1.4 | Effective Volume | 270L |
| 1.5 | Internal Chamber Dimensions | 600×900×500(W*H*D)(mm) |
| 1.6 | External Dimensions | 800×1400×1000(W*H*D)(mm) |
| 1.7 | Brine Tank Volume | 25L |
| 1.8 | Test Temperature | Neutral Salt Spray Test:
a. Test Chamber: 35℃±1℃ b. Saturated Air Tank: 47℃±1℃ Acid Corrosion Test: a. Test Chamber: 50℃±1℃ b. Saturated Air Tank: 63℃±1℃ It can also be set according to standards such as JIS and CNS |
| 1.9 | Applicable Test Methods | Neutral Salt Spray Test (NSS Test),
Acetic Acid Salt Spray Test (ASS Test), Copper Accelerated Acetic Acid Salt Spray Test (CASS Test) |
| 1.10 | Temperature Display Precision | Temperature: 0.1℃ |
| 1.11 | Temperature Deviation | Temperature: ±2℃ |
| 1.12 | Temperature Fluctuation | Temperature: ≤±0.5℃ |
| 1.13 | Temperature Uniformity | Temperature: ≤2.5%℃ |
| 1.14 | Spray Rate | (ml/80cm²/h) 1.0~2.0 (Collected for at least 16 hours, take the average value) |
| 1.15 | Spray Pressure | 1.00±0.01kgf/cm² |
| 1.16 | Operation Time | 1S ~ 9990H, arbitrarily settable |
| 1.17 | Spray Time | 1S ~ 999H, arbitrarily settable; Interval Cycle: 1S ~ 999H, arbitrarily settable |
| 1.18 | Weight | 150KG |
| 1.19 | Power | 220V 3KW |
| 1.20 | Others | 1. The above performance indicators are data measured under the conditions of no load, no test samples, and ambient temperature of 25±2℃.
2. 70dB (1 meter away from the chamber door, 1.5 meters high). |
- Compliant Test Standards
| Item No. | Standards | Explanation of Standards |
| 2.1 | General standards | GB/T2423.17-2008 Test Methods for Salt Spray |
| GB/T 2423.18-2000 Basic Procedures for Electrical and Electronic Products Test Ka | ||
| GB/T10125-1997 Corrosion Tests in Artificial Atmospheres – Salt Spray Tests | ||
| GB/T10587-2006 Technical Conditions for Salt Spray Test Chambers | ||
| GB10593.2-1990 Methods for Measuring Environmental Parameters of Electrical and Electronic Products | ||
| GB/T1771-2007 Determination of Neutral Salt Spray Resistance of Paints and Varnishes | ||
| GJB150.11A-2009 Salt Spray Test for Military Equipment Laboratories | ||
| 2.2 | Acceptance Execution Standards | Manufacturing Standards: GB/T10586-2006, GB/T10592-2008 |
| Verification Standards: GB/T5170.2-2017, GB/T5170.5-2016 | ||
| Technical Standards: Acceptance according to the signed technical index requirements |
- Equipment Structure
| Item No. | Description | Technical Specification Parameters |
| 3.1 | Cabinet Structure | Both the inner and outer chambers of the machine are made of high-temperature, high-humidity, and high-corrosion resistant PP boards, welded by advanced endless belt three-dimensional reinforcement technology. The structure is solid, non-deformable, and elegant in appearance, suitable for various test specifications such as salt water spray and copper acetate tests. |
| 3.2 | Inner Chamber Material | 8mm thick PP board; overall full welding treatment to ensure the sealing performance of the inner chamber; bottom reinforcement design, bearing capacity ≥100KG average load. |
| 3.3 | Outer Shell Material | 8mm thick PP board |
| 3.4 | Thermal Insulation Material | Thermal insulation layer thickness is 80MM, insulation medium is glass fiber cotton. |
| 3.5 | Test Chamber Cover | Roof-type 110-degree perspective cover, allowing clear observation of the test conditions inside the chamber. |
| 3.6 | Isolation Water Tank | Seals the chamber cover with water to avoid salt spray leakage. |
| 3.7 | Saturated Air Tank | Located at the bottom of the control box, made of SUS#304 stainless steel plate, functioning as filtration, heating, and humidification. It purifies the air to reach saturated temperature and humidity before spraying through the nozzle. The saturator has an automatic water replenishment function. |
| 3.8 | Measuring Cylinder | Collects the spray volume of each test, with a maximum scale of 50ml each time. |
| 3.9 | Pressure Regulating Valve | Manually adjusts the intake pressure and spray pressure. Intake pressure is controlled at 0.3mPa; spray pressure is controlled at 0.07-0.17mPa. (The above pressures have been adjusted before leaving the factory, and generally, users do not need to adjust them again) |
| 3.10 | Pressure Gauge | The pressure displayed by the pressure gauge pointer is the pressure when the air from the saturated air tank is delivered to the nozzle for spraying. |
| 3.11 | Water Replenishment System(optional) | 1. Water replenishment for test chamber and pressure tank: Manual Two water replenishment control systems are available: manual and automatic. It supports dual water replenishment methods—automatic water supply via connection to a tap water pipeline or manual water addition—offering convenient operation.
Note: If the tap water contains excessive impurities or is acidic/alkaline, a filter must be installed at the water inlet. 2. Chemical solution replenishment: Adopts a built-in hidden large water tank, manual water replenishment method |
| 3.12 | Mist Discharge Pipe | 50mm diameter PVC hard plastic pipe, which releases the pressure caused by spraying when the salt spray test chamber is working, and the excess water in the chamber also overflows through this pipe. |
| 3.13 | Collector | The fine mist sprayed by the nozzle settles in a free-fall manner, with one or more built-in surface areas. |
| 3.14 | Heating Water Tank | Attached to the bottom of the test chamber, used to hold water and heat to maintain a stable temperature in the test chamber. |
| 3.15 | Shelf | Made of plastic steel, single-bar bearing capacity not exceeding 2kg; can bear weight within 10kg if placed dispersedly. Two layers, one-time molding with standard molds, can meet the inclined test of about 15 degrees ~ 30 degrees(Ensure that the experimental solution does not deposit). |
| 3.16 | Nozzle | Made of tempered glass, the spray volume and spray angle can be adjusted. Precision crystal glass nozzle (PYREX) without crystal blockage. |
| 3.17 | Electrical Control Cabinet | The circuit control board and other components are fixed in positions convenient for inspection and maintenance, adopting a door-lock opening side cover door, which is not only beautiful but also convenient for maintenance. |
| 3.18 | Control Panel | Touch screen control: Water shortage indicator, over-temperature indicator, end indicator, spray indicator, defogging indicator, test chamber temperature controller, pressure tank temperature controller, pressure gauge, main power switch, operation switch, timing switch, spray switch, defogging switch. |
- Spray System
| Item No. | Description | Technical Specification Parameters |
| 4.1 | Spray Device | Adopts a tower-type spray tower with functions of guiding mist, adjusting mist volume, and uniform fog falling, while effectively expanding the internal space of the test chamber. |
| 4.2 | Spray Gas Treatment | The spray gas undergoes two-stage voltage stabilization and pressure regulation, with oil pollution filtration and gas humidification and preheating simultaneously. |
| 4.3 | Atomization Treatment | The atomized salt water is stored in a built-in hidden type with a large storage capacity. |
| 4.4 | Pressure Control | Through intake pressure regulating valve, spray pressure regulating valve, and pressure gauge. Air pressure is adjusted in two stages: 1Kg/cm². The first stage is rough adjustment: 2Kg/cm², adopting imported air filter with drainage function. The second stage is precision adjustment: 1Kg/cm², 1/4 pressure gauge, displaying precisely and accurately. |
| 4.5 | Spray Volume | Increasing the conical disperser on the spray tower increases the spray volume; decreasing it reduces the spray volume. |
- Heating System
| Item No. | Description | Technical Specification Parameters |
| 5.1 | Heating Method | Adopts steam heating method, with fast heating speed and reduced standby time. When the temperature is reached, it automatically switches to constant temperature state, with precise temperature and low power consumption. Titanium alloy heating tube, acid and alkali corrosion resistant, with ultra-long service life. |
| 5.2 | Heating Tube | Adopts stainless steel finned nickel-chromium wire high-speed heater. |
| 5.3 | Heating System | Temperature control is realized by microcomputer calculation and PID automatic adjustment. The output power changes according to the comparison result between the actual temperature and the set temperature, so as to achieve high precision, high efficiency, and high stability. |
- Control System
| Item No. | Description | Technical Specification Parameters |
| 6.1 | Control Method | The controller adopts a 7-inch color LCD touchscreen + PLC program control module |
| 6.2 | Screen Display | Set temperature, actual measured temperature, total operation time, Display on the color LCD, and touchscreen-based input and setting. |
| 6.3 | Set Temperature | Adjust according to the temperature working range of the equipment (upper limit +5℃, lower limit -5℃) |
| 6.4 | Program Capacity | 20 programs, with each program supporting a maximum of 99 segments. Program segments can be cycled and linked. |
| 6.5 | Operation Mode | Constant value operation or program operation. |
| 6.6 | Display Precision | Temperature display:0.1℃
Time:1min |
| 6.7 | Login Method | Name login |
| 6.8 | Auxiliary Functions | Fault alarm and cause, processing prompt function, power failure protection function, upper and lower limit temperature protection function, timing function (automatic start and automatic stop operation). |
- Safety Protection Devices
| Item No. | Technical Specification Parameters |
| 7.1 | When the water level is low, automatically cut off the power supply, and the safety warning light device displays dynamically. |
| 7.2 | When over-temperature occurs, automatically cut off the heater power supply, and the safety warning light device displays dynamically. |
| 7.3 | Leakage protection function to prevent personal injury and instrument failure caused by line leakage or short circuit. |
| 7.4 | Heating system protection function: dry burning of heating tube, abnormal water supply, abnormal drainage |